An infrared electric radiator is a type of heater that converts electric power directly into heat, but unlike traditional convection heaters, it warms people and objects directly through infrared radiation, similar to natural sunlight. This provides instant, efficient, and silent warmth without first heating the surrounding air, making it ideal for spaces that require quick, targeted heating or for allergy sufferers, as it reduces air circulation. Infrared electric radiators are highly energy-efficient, converting nearly 100% of electricity into heat. They are available in various forms, including wall panels, portable units, and outdoor patio heaters, and often feature thermostats, timers, and remote controls for convenient temperature management.
AirTS-ES
Function: electric heating

Quality Assurance
Stable and Durable.

After-sales Service
24H Online.
Working principle
Infrared heating works as the waves radiated from the heat source travel unimpeded to surfaces,
objects and people, producing a natural warmth that feels much like the sun on a warm day.
This direct method of heating is exceptionally efficient as almost 100% of all energy used is converted into heat.
Based on infrared radiation heating technology, the filament is heated by an electric current to generate heat and
infrared radiation.
This heating method does not need to preheat in advance, ready to use, can quickly provide warmth,this radiation
can directly act on the human body, providing warmth at the same time, the thermal effect of infrared can promote
blood circulation, which has certain benefits for human health.
For the cold winter, it is an economical and effective way of heating.
Radiant energy emanates from a source in the form of electromagnetic waves in the infrared spectral band
1. Infrared is in the safe region of the spectrum, outside visible light
2. Infrared radiant heaters do not produce ultraviolet rays and other harmful radiation
3. Infrared rays only generate heat when they touch the surface of an object
4. Infrared transmission does not require a medium and can also propagate in a vacuum

Functions & Features
Instant and efficient heating
Clean and safe without open flame
Low maintenance

| Infrared Electric Radiator | ||||
| Model | AirTS-ES6000 | AirTS-ES8000 | AirTS-ES10000 | AirTS-ES12000 |
| Size (mm) | 1296x255x110 | 1728x255x110 | 2160x255x110 | 2592x255x110 |
| Voltage (V) | 380±5% | 380±5% | 380±5% | 380±5% |
| Frequency (Hz) | 50 | 50 | 50 | 50 |
| Electric power (kW) | 6 | 8 | 10 | 12 |
| Current (A) | 10.39 | 13.86 | 17.32 | 20.78 |
| Suitable Installation height (m) | 2~7.5 | 2~7.5 | 2~7.5 | 2~7.5 |
| Heating method | electric radiation | electric radiation | electric radiation | electric radiation |
| Service life (H) | 5000 | 5000 | 5000 | 5000 |
Spot heating for living rooms, offices, and other indoor spaces requiring quick, localized warmth.
Workshops and garages with drafts or poor insulation, where efficient directional heating is needed.
Outdoor patios and commercial areas, providing comfortable heat without warming the surrounding air.
Residential use for allergy sufferers, as infrared heating minimizes air circulation and dust movement.
Selecting an infrared electric radiator requires more than matching the rated power to the floor area. Ceiling height, insulation, air movement, surrounding surfaces, target temperature, and the location of occupants or work areas all affect the heating result.
Consider the 6 kW configuration when the required radiant output, installation conditions, and project heating assessment support the lower power option within the available range.
Before specifying this model, evaluate the dimensions of the heated zone, mounting height, ambient temperature, and whether one or multiple units are needed.
The 8 kW configuration provides a higher rated electrical heating capacity than the 6 kW model. It may be worth evaluating for a project requiring more output, subject to the installation layout and heat-loss assessment.
Confirm the available electrical supply and installation clearances before selecting the unit.
The 10 kW option can be considered where the project requires a higher rated heating capacity and the electrical infrastructure can support the load.
For larger or irregular spaces, determine whether multiple heating zones would provide better coverage than a single high-output unit.
The 12 kW configuration offers the highest rated power in the listed ES series. It may be suitable for applications requiring a higher output, provided the mounting conditions, electrical supply, and project heating requirements are compatible.
Do not select a model based on power alone. Request a heating assessment when the project has high ceilings, substantial heat loss, or specific temperature targets.
Before installing an infrared electric radiator, confirm that the selected model matches the available electrical supply and intended mounting arrangement.
● Electrical capacity: Verify voltage, phase, circuit capacity, wiring, and overcurrent protection with a qualified electrician.
● Mounting position: Confirm the permitted installation orientation, mounting structure, and clearance from surrounding objects.
● Heating coverage: Check the relationship between installation height, radiation direction, target area, and potential obstructions.
● Environmental suitability: Confirm the product's permitted ambient conditions and any required ingress protection before using it in damp or exposed areas.
● Control arrangement: Determine whether the installation requires external switching, temperature control, or multiple independently controlled heating zones.
Follow the manufacturer's installation instructions and applicable electrical and building regulations. Do not commission the equipment until all electrical and mounting requirements have been verified.
Start with the heated area, ceiling height, insulation, ambient conditions, target temperature, and operating schedule. Compare these requirements with the available 6–12 kW models and request a heating assessment when the project has substantial heat loss or complex coverage requirements.
The published specifications list 380 ± 5% V and 50 Hz for the four ES models. Confirm the electrical supply, phase arrangement, and installation requirements against the current datasheet before ordering.
The published suggested installation height for the listed ES models is 2–7.5 m. Confirm the installation instructions and assess the target heating area before finalizing the mounting position.
At continuous full rated power, a 6 kW unit uses 6 kWh per hour, while a 12 kW unit uses 12 kWh per hour. Actual consumption depends on operating duration, control strategy, and the heating demand.
They can be considered for suitable workshop and warehouse applications, particularly where targeted radiant heating is useful. The installation height, heating layout, electrical capacity, and environmental conditions must be evaluated for the specific site.
Outdoor use depends on the product's environmental rating and installation instructions. Confirm weather protection, mounting conditions, electrical protection, and permitted exposure before specifying the unit for outdoor operation.
AirTs is a professional brand dedicated to efficient and reliable heating solutions, specializing in the design and manufacture of high-performance Infrared radiant heaters. With a strong focus on energy efficiency, comfort, and modern design, AirTs products deliver instant, quiet, and targeted warmth for residential, commercial, and outdoor applications. Backed by strict quality control and continuous innovation, AirTs is committed to providing safe, durable, and user-friendly infrared heating solutions that meet the needs of today’s living and working environments.
Contact AirTs today to learn more about our infrared heating solutions or to request a customized quote.
Look forward to hearing from you
Welcome friends and customers at home and abroad to cooperate sincerely and create brilliance together!
Service E-mail: [email protected]